Accton Technology ES4710BD User Manual

Browse online or download User Manual for Chassis components Accton Technology ES4710BD. Accton Technology ES4710BD User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 547
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
www.edge-core.com
ES4710BD
10 Slots L2/L3/L4 Chassis Switch
Users Guide
Page view 0
1 2 3 4 5 6 ... 546 547

Summary of Contents

Page 1 - User’s Guide

www.edge-core.com ES4710BD 10 Slots L2/L3/L4 Chassis Switch User’s Guide

Page 2 - Preface

9EES4710BD 10 Slots L2/L3/L4 Chassis Switch 6.4.1 Reset specific module...

Page 3 - Content

99EES4710BD 10 Slots L2/L3/L4 Chassis Switch Telnet is a simple remote terminal protocol for remote login. Using Telnet, the user can login to a

Page 4

100EES4710BD 10 Slots L2/L3/L4 Chassis Switch information. 2. Telnet to a remote host from the switch 5.2.2.3 Telnet Commands 5.2.2.3.1 mon

Page 5

101EES4710BD 10 Slots L2/L3/L4 Chassis Switch Connecting Host 20.1.1.123 Port 23... Service port is 23 Connected to 20.1.1.123login:123 password

Page 6

102EES4710BD 10 Slots L2/L3/L4 Chassis Switch command deletes the specified Telnet user. Parameters: <username> is the Telnet client’s

Page 7

103EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch#show clock Current time is TUE AUG 22 11:00:01 2002 Related command: clock set 5.2.4.2 s

Page 8

104EES4710BD 10 Slots L2/L3/L4 Chassis Switch enable config interface ethernet 1/3 enable show flash show ftp 5.2.4.5 show memory Command: sh

Page 9

105EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch#show running-config 5.2.4.7 show startup-config Command: show startup-config Function: D

Page 10

106EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.2.4.9 show tcp Command: show tcp Function: Displays the current TCP connection status establish

Page 11

107EES4710BD 10 Slots L2/L3/L4 Chassis Switch Example: Switch#show telnet login Authenticate login by local. Login user: aa Switch# 5.2.4.12

Page 12

108EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.3 Configuring Switch IP Addresses All Ethernet ports of ES4710BD perform layer 2 forwarding. Th

Page 13

10EES4710BD 10 Slots L2/L3/L4 Chassis Switch 7.2.4.1 Introduction to Port Mirroring...

Page 14

109EES4710BD 10 Slots L2/L3/L4 Chassis Switch 3.DHCP Command Explanation ip dhcp-client enable no ip dhcp-client enable Enables the switch to be

Page 15

110EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch(Config)#interface vlan 1 Switch(Config-If-Vlan1)#ip bootp-client enable Switch (Config-If-V

Page 16

111EES4710BD 10 Slots L2/L3/L4 Chassis Switch SNMP protocol provide a relatively direct way of exchanging management information between two poi

Page 17

112EES4710BD 10 Slots L2/L3/L4 Chassis Switch Fig 5-1 ASN.1 tree instance In this figure, the OID of object A is 1.2.1.1. NMS can find this

Page 18

113EES4710BD 10 Slots L2/L3/L4 Chassis Switch Statistics: Maintains basic utilization and error statistics for each subnet monitored by the Agen

Page 19

114EES4710BD 10 Slots L2/L3/L4 Chassis Switch configured secure address. 4. Configuring TRAP Command Explanation snmp-server enable traps no snm

Page 20

115EES4710BD 10 Slots L2/L3/L4 Chassis Switch Parameters: <string> is the community string set; ro|rw is the specified access mode to MIB,

Page 21

116EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.4.4.2.5 snmp-server host Command: snmp-server host <host-addr> <community-string>

Page 22

117EES4710BD 10 Slots L2/L3/L4 Chassis Switch 1. 1. 1. 51. 1. 1. 9 Fig 5-2 SNMP Configuration Example The IP address of NMS is 1.1.1.5; the Swi

Page 23

118EES4710BD 10 Slots L2/L3/L4 Chassis Switch Function: Displays all SNMP counter information. Command mode: Admin Mode Example: Switch#show

Page 24

11EES4710BD 10 Slots L2/L3/L4 Chassis Switch 8.4.1.1 show mac-address-table aging-time ...

Page 25

119EES4710BD 10 Slots L2/L3/L4 Chassis Switch MIB objects bad values errors Number of “Bad_values” error SNMP packets general errors Number o

Page 26

120EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.4.6.1.3 debug snmp packet Command: debug snmp packet no debug snmp packet Function: Enabl

Page 27

121EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.5.1 BootROM Upgrade There are two methods for BootROM upgrade: TFTP and FTP, which can be sele

Page 28

122EES4710BD 10 Slots L2/L3/L4 Chassis Switch 219.32 BogoMIPS SST39VF040

Page 29

123EES4710BD 10 Slots L2/L3/L4 Chassis Switch mirror file. [Boot]: write nos.img Programming... Program OK. [Boot]: Step 6: After successful

Page 30

124EES4710BD 10 Slots L2/L3/L4 Chassis Switch to establish management connection on port 21 in the server, and negotiate a data connection throu

Page 31

125EES4710BD 10 Slots L2/L3/L4 Chassis Switch backup and update of the configurations. Start up configuration file: refers to the configurat

Page 32 - 1.1 Product Brief

126EES4710BD 10 Slots L2/L3/L4 Chassis Switch 1. FTP/TFTP client configuration (1)FTP/TFTP client upload/download file Command Explanation Adm

Page 33 - 1.1.2 Features

127EES4710BD 10 Slots L2/L3/L4 Chassis Switch 3. TFTP server configuration (1)Start TFTP server Command Explanation Global Mode tftp-server en

Page 34

128EES4710BD 10 Slots L2/L3/L4 Chassis Switch Special Keywords in filename keyword Source/Target IP address running-config Active configuratio

Page 35 - 1.1.3 Main Features

12EES4710BD 10 Slots L2/L3/L4 Chassis Switch 8.6.2.2.5 Clearing port MAC...

Page 36 -  MIB Library

129EES4710BD 10 Slots L2/L3/L4 Chassis Switch Example: viewing the file list of the FTP server 10.1.1.1 with the username “Switch” and password

Page 37 - 1.4 Hardware Components

130EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.5.2.2.7 ip ftp Command:ip ftp <username> password [type{0|7}] <password> no ip ftp

Page 38 - 1.4.1.1 Board Rack

131EES4710BD 10 Slots L2/L3/L4 Chassis Switch Usage Guide: The command provides command line prompt messages. If the user enters a command like

Page 39 - 1.4.1.2 Power Supply

132EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.5.2.2.10 tftp-server retransmission-number Command: tftp-server retransmission-number <num

Page 40 - 1.4.2.1 EM4710BD-AGENT

133EES4710BD 10 Slots L2/L3/L4 Chassis Switch Scenario 1: The switch is used as FTP/TFTP client. The switch connects from one of its ports to a

Page 41

134EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch (Config)#inter vlan 1 Switch (Config-If-Vlan1)#ip address 10.1.1.2 255.255.255.0 Switch (

Page 42 - 1.4.2.2 EM4700BD-12GT-RJ45

135EES4710BD 10 Slots L2/L3/L4 Chassis Switch “edgecore”. Save “Profile1”, “Profile2” and “Profile3” in the appropriate FTP server directory

Page 43 - 1.4.2.3.1 Front Panel

136EES4710BD 10 Slots L2/L3/L4 Chassis Switch FTP Configuration PC side: Start the FTP server software on the PC and set the username as “Swi

Page 44

137EES4710BD 10 Slots L2/L3/L4 Chassis Switch Example: Switch#show ftp Timeout :600 Displayed information Description Timeout Timeout time

Page 45 - 1.4.2.4.1 Front Panel

138EES4710BD 10 Slots L2/L3/L4 Chassis Switch send file 150 Opening ASCII mode data connection for nos.img. 226 Transfer complete. close ftp

Page 46

13EES4710BD 10 Slots L2/L3/L4 Chassis Switch 9.5.1.1 Create/remove Vlan ...

Page 47

139EES4710BD 10 Slots L2/L3/L4 Chassis Switch & The following is the message displayed when files are successfully received. Otherwise,

Page 48

140EES4710BD 10 Slots L2/L3/L4 Chassis Switch z Basic host configuration – configures the mapping relationship between the switch and the IP a

Page 49

141EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.6.2.2 Trap manager configuration Users should click “Switch basic configuration”, “SNMP co

Page 50

142EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.6.2.4 SNMP statistics When users click “Switch basic configuration”, “SNMP configuration” and

Page 51 - 1.4.7 Dust Gauze

143EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.6.3 Switch upgrade Users should click “Switch basic configuration” and “Switch update” to confi

Page 52 - 1.4.9 Side Panels

144EES4710BD 10 Slots L2/L3/L4 Chassis Switch Server state-status of the server. (“Open” or “Close”) Please refer to the CLI command 5.5.2.2.10

Page 53 - 1.5 System Features

145EES4710BD 10 Slots L2/L3/L4 Chassis Switch configuration.” Words and phrases of “user configuration” are explained in the following: z FTP

Page 54 - 2.1 Safety Information

146EES4710BD 10 Slots L2/L3/L4 Chassis Switch z Show telnet user-to display all Telnet client messages with authenticated switch access through

Page 55

147EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.6.4.3 Others Other parts are easier to configure. Users just click a configuration node and th

Page 56 - 2.1.1 Site Requirements

148EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.6.6 Switch on-off information Users should click “Switch on-off information” to enter into the

Page 57 - 2.1.3 Dust and Particles

14EES4710BD 10 Slots L2/L3/L4 Chassis Switch 10.2.2.9 spanning-tree link-type p2p...

Page 58 - 2.1.6 Rack Configuration

149EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.6.7.2 Exit current web configuration Users should quit the web-login by clicking “Switch mainte

Page 59 - Accessories

150EES4710BD 10 Slots L2/L3/L4 Chassis Switch z Telnet server State-to choose from the drop-down list. (“Open” and “Close” service) Please ref

Page 60 - 2.3 Hardware Installation

151EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 6 Device Management 6.1 Device Management Brief The device management function of ES47

Page 61

152EES4710BD 10 Slots L2/L3/L4 Chassis Switch Example: Switch # show slot M1 ------------------Slot : M1------------------

Page 62 - 2.3.1 Switch Installation

153EES4710BD 10 Slots L2/L3/L4 Chassis Switch Example: Switch # show power ----------power information----------

Page 63 - 2.3.2 Switch grounding

154EES4710BD 10 Slots L2/L3/L4 Chassis Switch If the cards need to be replaced during normal operation, the following guidelines should be foll

Page 64

155EES4710BD 10 Slots L2/L3/L4 Chassis Switch 6.4.1 Reset specific module Click “Device management”, “Reset specific module”, select a module

Page 65

156EES4710BD 10 Slots L2/L3/L4 Chassis Switch 6.4.3 Show fan Click “Device management”, “Show power”. The information column displayed on the

Page 66

157EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 7 Port Configuration 7.1 Introduction to Port ES4710BD comes with line cards and maste

Page 67

158EES4710BD 10 Slots L2/L3/L4 Chassis Switch 7.2 Port Configuration 7.2.1 Network Port Configuration 7.2.1.1 Network Port Configuration Task

Page 68

15EES4710BD 10 Slots L2/L3/L4 Chassis Switch 10.5.4 Show MSTP setting...

Page 69

159EES4710BD 10 Slots L2/L3/L4 Chassis Switch speed-duplex {auto | force10-half | force10-full | force100-half | force100-full | { {force1g-half

Page 70

160EES4710BD 10 Slots L2/L3/L4 Chassis Switch the port. For example, a bandwidth limit of 101 M (or more) cannot be set for a 10/100M Ethernet p

Page 71 - 3.1 Setup Configuration

161EES4710BD 10 Slots L2/L3/L4 Chassis Switch Note: & Combo port is a conception involving the physical layer and the LLC sublayer of the d

Page 72 - 3.1.2 Setup Submenu

162EES4710BD 10 Slots L2/L3/L4 Chassis Switch 7.2.1.2.4 interface ethernet Command: interface ethernet <interface-list> Function: Enters

Page 73

163EES4710BD 10 Slots L2/L3/L4 Chassis Switch Example: Setting the cable type support of Ethernet ports 3/5 – 8 to straight-through cable only.

Page 74

164EES4710BD 10 Slots L2/L3/L4 Chassis Switch 7.2.1.2.9 rate-suppression Command: rate-suppression {dlf | broadcast | multicast} <packets>

Page 75

165EES4710BD 10 Slots L2/L3/L4 Chassis Switch 7.2.1.2.11 speed-duplex Command: speed-duplex {auto | force10-half | force10-full | force100-half

Page 76 - 3.1.2.5 Configuring SNMP

166EES4710BD 10 Slots L2/L3/L4 Chassis Switch 2. Configure the IP address for VLAN interface and enables VLAN interface. Command Explanation VL

Page 77

167EES4710BD 10 Slots L2/L3/L4 Chassis Switch Parameters: <ip-address> is the IP address in decimal format; <mask> is the subnet ma

Page 78

168EES4710BD 10 Slots L2/L3/L4 Chassis Switch 2. Configure the properties for the network management port Command Explanation Network Managemen

Page 79 - 4.1 Management Options

16EES4710BD 10 Slots L2/L3/L4 Chassis Switch 12.1.3 Access list Action and Global Default Action ...

Page 80

169EES4710BD 10 Slots L2/L3/L4 Chassis Switch 7.2.3.2.2 interface ethernet Command: interface ethernet <interface-name> Function: Enters

Page 81

170EES4710BD 10 Slots L2/L3/L4 Chassis Switch 7.2.3.2.5 shutdown Command: shutdown no shutdown Function: Shuts down the network manageme

Page 82 - SWITCH#

171EES4710BD 10 Slots L2/L3/L4 Chassis Switch mirror destination port. A protocol analyzer (such as Sniffer) or RMON monitoring instrument is of

Page 83 - 4.1.2 In-band Management

172EES4710BD 10 Slots L2/L3/L4 Chassis Switch Parameters: <session> stands for mirror session value, only 1 may be used at present; <i

Page 84

173EES4710BD 10 Slots L2/L3/L4 Chassis Switch Function: Displays information about mirror source/destination ports. Command mode: Admin Mode U

Page 85 - Switch#config

174EES4710BD 10 Slots L2/L3/L4 Chassis Switch No VLAN has been configured in the switches, default VLAN1 is used. Switch Port Property SW1 2/

Page 86 - 4.2 Management Interface

175EES4710BD 10 Slots L2/L3/L4 Chassis Switch Default: Port statistics are not cleared by default. Usage Guide: If no port is specified, then

Page 87 - 4.2.1.1 Configuration Modes

176EES4710BD 10 Slots L2/L3/L4 Chassis Switch 7.5.1 Ethernet port configuration Click “Port configuration”, “Ethernet port configuration” to op

Page 88 - 4.2.1.1.3.1 Interface Mode

177EES4710BD 10 Slots L2/L3/L4 Chassis Switch z Bandwidth control level: port bandwidth control. The unit is Mbps and the value range is 1~1000

Page 89 - 4.2.1.1.3.5 ACL Mode

178EES4710BD 10 Slots L2/L3/L4 Chassis Switch 7.5.2.2 L3 port IP addr mode configuration Click “Port configuration”, “vlan interface con

Page 90

17EES4710BD 10 Slots L2/L3/L4 Chassis Switch 13.4 PORT CHANNEL TROUBLESHOOTING HELP ...

Page 91 - 4.2.1.5 Input verification

179EES4710BD 10 Slots L2/L3/L4 Chassis Switch Configure mirroring destination port. Equals to CLI command 7.2.3.3.2. z Session: Mirroring dialo

Page 92 - 4.3.1 Main Page

180EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 8 MAC Table Configuration 8.1 Introduction to MAC Table MAC table identifies the mapp

Page 93 - 4.3.2 Module Front Panel

181EES4710BD 10 Slots L2/L3/L4 Chassis Switch period. When the switch receives a data frame to be forwarded, it stores the source MAC address of

Page 94 - 5.1.3 enable

182EES4710BD 10 Slots L2/L3/L4 Chassis Switch added to the switch MAC table. 2. At the same time, the switch learns the message is destined t

Page 95 - 5.1.5 exec timeout

183EES4710BD 10 Slots L2/L3/L4 Chassis Switch are configured in the switch, the MAC table will be adapted accordingly to add VLAN information. I

Page 96 - 5.1.8 ip host

184EES4710BD 10 Slots L2/L3/L4 Chassis Switch no mac-address-table [{static | dynamic} [address <mac-addr>] [vlan <vlan-id>] [interf

Page 97 - 5.1.11 set default

185EES4710BD 10 Slots L2/L3/L4 Chassis Switch 1/ 7 1/ 91/ 111/ 5PC1MAC 00-01-11-11-11-11PC4MAC 00-01-44-44-44-44PC3MAC 00-01-33-33-33-33PC2MA

Page 98 - 5.2.1 ping

186EES4710BD 10 Slots L2/L3/L4 Chassis Switch 8.4.1.2 show mac-address-table static Command: show mac-address-table [static] [address <mac

Page 99 - 5.2.2 Telnet

187EES4710BD 10 Slots L2/L3/L4 Chassis Switch support for a solution. 8.5 MAC Address Function Extension 8.5.1 MAC Address Binding 8.5.1.1

Page 100

188EES4710BD 10 Slots L2/L3/L4 Chassis Switch 2. Lock the MAC addresses for a port Command Explanation Interface Mode switchport port-secur

Page 101 - 5.2.2.3 Telnet Commands

18EES4710BD 10 Slots L2/L3/L4 Chassis Switch 14.5 DHCP TROUBLESHOOTING HELP ...

Page 102 - 5.2.2.3.5 telnet-user

189EES4710BD 10 Slots L2/L3/L4 Chassis Switch 8.5.1.2.2 MAC Address Binding Configuration Commands 8.5.1.2.2.1 switchport port-security Co

Page 103 - 5.2.4.1 show clock

190EES4710BD 10 Slots L2/L3/L4 Chassis Switch Function: Locks the port. When a port is locked, the MAC address learning function for the port wi

Page 104 - 5.2.4.4 show history

191EES4710BD 10 Slots L2/L3/L4 Chassis Switch address can be added. Example: Adding MAC 00-03-0F-FE-2E-D3 to port1. Switch(Config)#interface Eth

Page 105 - 5.2.4.5 show memory

192EES4710BD 10 Slots L2/L3/L4 Chassis Switch 8.5.1.2.2.8 switchport port-security violation Command: switchport port-security violation {prote

Page 106

193EES4710BD 10 Slots L2/L3/L4 Chassis Switch Displayed information Explanation Security Port Name of port that is configured as a secur

Page 107 - 5.2.4.11 show telnet login

194EES4710BD 10 Slots L2/L3/L4 Chassis Switch Port Security Is port enabled as a secure port? Port status Port secure status Violation mode V

Page 108 - 5.2.5 debug

195EES4710BD 10 Slots L2/L3/L4 Chassis Switch 8.5.1.3.2 MAC Address Binding Troubleshooting Help Enabling MAC address binding for ports may

Page 109

196EES4710BD 10 Slots L2/L3/L4 Chassis Switch 8.6.1.2 Delete unicast address Click “MAC address table configuration”, “MAC address table conf

Page 110 - 5.3.2.1 ip address

197EES4710BD 10 Slots L2/L3/L4 Chassis Switch Example: Select VID 1 and select query by VID. Click Search starting query. The new page will sho

Page 111 - 5.4 Configuring SNMP

198EES4710BD 10 Slots L2/L3/L4 Chassis Switch 8.6.2.1 Enable port MAC-Binding Click “MAC address table configuration”, “MAC address binding con

Page 112 - 5.4.2 Introduction to MIB

1EES4710BD 10 Slots L2/L3/L4 Chassis Switch Preface ES4710BD is a high performance routing switch released by Edge-Core that can be deployed as

Page 113 - 5.4.3 Introduction to RMON

19EES4710BD 10 Slots L2/L3/L4 Chassis Switch 15.3.1.1 show sntp...

Page 114 - 5.4.4 Configuring SNMP

199EES4710BD 10 Slots L2/L3/L4 Chassis Switch 8.6.2.2.3 Enable port security timeout Click “MAC address table configuration”, “MAC address b

Page 115 - 5.4.4.2.1 rmon

200EES4710BD 10 Slots L2/L3/L4 Chassis Switch 8.6.2.3 MAC binding attribution configuration Click “MAC address table configuration”, “MAC ad

Page 116

201EES4710BD 10 Slots L2/L3/L4 Chassis Switch 8.6.2.4 MAC binding debug Click “MAC address table configuration”, “MAC address binding configura

Page 117 - 5.4.4.2.5 snmp-server host

202EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 9 VLAN Configuration 9.1 Introduction to VLAN VLAN (Virtual Local Area Network) is

Page 118 - 1. 1. 1. 9

203EES4710BD 10 Slots L2/L3/L4 Chassis Switch conveniences: z Improved network performance z Savings on network resources z Simplified Netwo

Page 119

204EES4710BD 10 Slots L2/L3/L4 Chassis Switch 4. Set The Switch Port Type 5. Set Trunk port 6. Set Access port 7. Disable/Enable VLAN Ingres

Page 120 - 5.4.6.1.2 show snmp status

205EES4710BD 10 Slots L2/L3/L4 Chassis Switch configure a VLAN name and the switch ports assigned to the VLAN. The “no vlan <vlan-id>” com

Page 121 - 5.5 Switch Upgrade

206EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch(Config-ethernet1/8)#switchport mode access Switch(Config-ethernet1/8)#switchport access vla

Page 122 - 5.5.1 BootROM Upgrade

207EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command: switchport trunk allowed vlan {<vlan-list>|all} no switchport trunk allowed vlan

Page 123

208EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command mode: Interface Mode Default: VLAN ingress rules are enabled by default. Usage Guide

Page 124 - 5.5.2 FTP/TFTP Upgrade

20EES4710BD 10 Slots L2/L3/L4 Chassis Switch 16.4.1.4 show mls qos maps...

Page 125

209EES4710BD 10 Slots L2/L3/L4 Chassis Switch VLAN200 Site A and site B switch port 8 – 10. Trunk port Site A and site B switch port 11 . Co

Page 126

210EES4710BD 10 Slots L2/L3/L4 Chassis Switch 9.3 GVRP Configuration GARP (Generic Attribute Registration Protocol) can be used to dynamically

Page 127

211EES4710BD 10 Slots L2/L3/L4 Chassis Switch 9.3.2 GVRP Commands 9.3.2.1 garp timer join Command: garp timer join <timer-value> no

Page 128 - 5.5.2.2.3 copy(FTP)

212EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch(Config-Ethernet1/10)#garp timer leave 3000 9.3.2.3 garp timer hold Command: garp timer ho

Page 129 - 5.5.2.2.4 dir

213EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command mode: Interface Mode and Global Mode. Default: GVRP is disabled by default. Usage Guid

Page 130 - Switch” and password

214EES4710BD 10 Slots L2/L3/L4 Chassis Switch Configuration Item Configuration description VLAN100 Port 2 – 6 of Switch A and C Trunk port Por

Page 131 - 5.5.2.2.8 copy(TFTP)

215EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch(Config-Ethernet1/11)#switchport mode trunk Switch(Config-Ethernet1/11)#gvrp Switch(Config-E

Page 132

216EES4710BD 10 Slots L2/L3/L4 Chassis Switch Total Existing Vlans is:2 Displayed information Explanation VLAN VLAN number Name VLAN name T

Page 133 - 10. 1. 1. 2

217EES4710BD 10 Slots L2/L3/L4 Chassis Switch debugging function. Command mode: Admin Mode Default: GVRP debugging information is disabled by de

Page 134

218EES4710BD 10 Slots L2/L3/L4 Chassis Switch VLAN ID information window will display current VLANs of the switch: 9.5.1.1.2 VID attribut

Page 135

21EES4710BD 10 Slots L2/L3/L4 Chassis Switch 17.2.1 Introduction to IP Forwarding...

Page 136

219EES4710BD 10 Slots L2/L3/L4 Chassis Switch Information display shows the VLAN allocation result: 9.5.1.3 Port type configuration Click

Page 137 - 5.5.2.4.2 show ftp

220EES4710BD 10 Slots L2/L3/L4 Chassis Switch 9.5.1.4 Trunk port configuration Click “Vlan configuration”, “Vlan configuration”, “Trunk por

Page 138 - 5.5.2.4.3 show tftp

221EES4710BD 10 Slots L2/L3/L4 Chassis Switch 9.5.1.5 Set allow Vlan Click “Vlan configuration”, “Vlan configuration”, “Access port configu

Page 139

222EES4710BD 10 Slots L2/L3/L4 Chassis Switch Click “Vlan configuration”, “Vlan configuration”, “Enable/Disable Vlan filter rule” to open VLAN i

Page 140 - 5.6 WEB MANAGEMENT

223EES4710BD 10 Slots L2/L3/L4 Chassis Switch Click “Vlan configuration”, “GVRP configuration”, “GVRP configuration” to configure GVRP parameter

Page 141 - 5.6.2 SNMP configuration

224EES4710BD 10 Slots L2/L3/L4 Chassis Switch 9.5.3.2 Show GARP Click “Vlan configuration”, “Vlan debug” and “maintenance”, “show garp” The in

Page 142

225EES4710BD 10 Slots L2/L3/L4 Chassis Switch spanning tree instances (MSTI). It applies the fast converging properties, enabling multiple VLAN

Page 143 - 5.6.2.4 SNMP statistics

226EES4710BD 10 Slots L2/L3/L4 Chassis Switch CIST Regional Root. The root port in the Field CIST Regional Root is Master Port to all the MSTI i

Page 144 - 5.6.3 Switch upgrade

227EES4710BD 10 Slots L2/L3/L4 Chassis Switch 10.2 MSTP Configuration 10.2.1 MSTP configuration task sequence 1. Enable MSTP and set the run

Page 145

228EES4710BD 10 Slots L2/L3/L4 Chassis Switch 4. Configure MSTP time parameters 5. Configure the fast migrate feature for MSTP Command Explanat

Page 146

22EES4710BD 10 Slots L2/L3/L4 Chassis Switch 18.2.3.2.1 ip route ...

Page 147 - 5.6.4.1 Debug command

229EES4710BD 10 Slots L2/L3/L4 Chassis Switch 10.2.2 Introduction to MSTP configuration commands 10.2.2.1 abort Command: abort Function: D

Page 148 - 5.6.4.3 Others

230EES4710BD 10 Slots L2/L3/L4 Chassis Switch to Instance 0. Usage Guide: This command is used to set VLAN-Instance mapping. Switches are cons

Page 149 - 5.6.7 Switch Maintenance

231EES4710BD 10 Slots L2/L3/L4 Chassis Switch 10.2.2.6 spanning-tree Command: spanning-tree no spanning-tree Function: Enables MSTP in Global

Page 150

232EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command mode: Global Mode Default: The default Hello time is 2 seconds. Usage Guide: The interva

Page 151 - 5.6.8.2 Telnet security IP

233EES4710BD 10 Slots L2/L3/L4 Chassis Switch Bridge_Max_Age >= 2 ×(Bridge_Hello_Time + 1.0 seconds) Example: Setting the maximum age time to

Page 152 - 6.1 Device Management Brief

234EES4710BD 10 Slots L2/L3/L4 Chassis Switch 10.2.2.13 spanning-tree mode Command: spanning-tree mode {mstp|stp} no spanning-tree mode Funct

Page 153 - 6.2.2.1.3 show power

235EES4710BD 10 Slots L2/L3/L4 Chassis Switch 10.2.2.15 spanning-tree mst cost Command: spanning-tree mst <instance-id> cost <cost&g

Page 154 - 6.3 Card Hot-Swap Operation

236EES4710BD 10 Slots L2/L3/L4 Chassis Switch priority. Example: Setting the priority for port 1/2 of instance1 to 32. Switch(Config)#interfa

Page 155 - 6.4 WEB MANAGEMENT

237EES4710BD 10 Slots L2/L3/L4 Chassis Switch 10.3 MSTP Example The following is a typical MSTP application scenario: SW1SW2SW3SW411223542316

Page 156

238EES4710BD 10 Slots L2/L3/L4 Chassis Switch Port 4 200000 200000 Port 5 200000 200000 Port 6 200000 200000 Port 7 2000

Page 157 - 6.4.5 Show module in slot

23EES4710BD 10 Slots L2/L3/L4 Chassis Switch 18.4 OSPF ...

Page 158 - 7.1 Introduction to Port

239EES4710BD 10 Slots L2/L3/L4 Chassis Switch SW2(Config)#spanning-tree Switch SW3: SW3(Config)#vlan 20 SW3(Config-Vlan20)#exit SW3(Config)#v

Page 159 - 7.2 Port Configuration

240EES4710BD 10 Slots L2/L3/L4 Chassis Switch SW4(Config-Port-Range)#exit SW4(Config)#spanning-tree SW4(Config)#spanning-tree mst 4 priority 0

Page 160 - 7.2.1.2.1 bandwidth

241EES4710BD 10 Slots L2/L3/L4 Chassis Switch SW2SW3SW4235423675467 x x x x Figure 00-4 Instance3 topology in the MSTP field after MSTP c

Page 161 - 7.2.1.2.2 combo-forced-mode

242EES4710BD 10 Slots L2/L3/L4 Chassis Switch MSTP information can be displayed with the “show spanning-tree” command. Example: Displaying M

Page 162 - 7.2.1.2.3 flow control

243EES4710BD 10 Slots L2/L3/L4 Chassis Switch ########################### Instance 4 ########################### Self Bridge Id : 32768.00:

Page 163 - 7.2.1.2.6 mdi

244EES4710BD 10 Slots L2/L3/L4 Chassis Switch 10.4.1.2 show mst configuration Command: show spanning-tree mst config Function: Displays the eff

Page 164 - 7.2.1.2.8 negotiation

245EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch(Config-Mstp-Region)# 10.4.1.4 debug spanning-tree Command: debug spanning-tree

Page 165 - 7.2.1.2.10 shutdown

246EES4710BD 10 Slots L2/L3/L4 Chassis Switch 10.5 WEB MANAGEMENT Click “MSTP control” to enter MSTP control configuration mode to manage MSTP

Page 166 - 7.2.1.2.11 speed-duplex

247EES4710BD 10 Slots L2/L3/L4 Chassis Switch 10.5.2 MSTP port operation 10.5.2.1 Edge port setting Click “MSTP control” to enter MSTP field o

Page 167 - 7.2.2.2.2 ip address

248EES4710BD 10 Slots L2/L3/L4 Chassis Switch 10.5.2.5 Link type configuration Click “MSTP control” to enter MSTP port operation, then "Li

Page 168 - 7.2.2.2.3 shutdown

24EES4710BD 10 Slots L2/L3/L4 Chassis Switch 18.4.2.2.34 debug ip ospf spf...

Page 169 - 7.2.3.2.1 duplex

249EES4710BD 10 Slots L2/L3/L4 Chassis Switch Click “MSTP control” to enter MSTP Global control, then "Hello_time Config". Set the H

Page 170 - 7.2.3.2.4 loopback

250EES4710BD 10 Slots L2/L3/L4 Chassis Switch Click “MSTP control”, “MSTP Global control”, enter the "Priority Config" to set bridge p

Page 171 - 7.2.3.2.6 speed

251EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter11 IGMP Snooping Configuration 11.1 Introduction to IGMP Snooping IGMP (Internet Group Ma

Page 172

252EES4710BD 10 Slots L2/L3/L4 Chassis Switch ip igmp snooping vlan <vlan-id> no ip igmp snooping vlan <vlan-id> Enables IGMP Snoopi

Page 173 - 7.2.4.5.1.1 show monitor

253EES4710BD 10 Slots L2/L3/L4 Chassis Switch command disables the IGMP Snooping function. Command mode: Global Mode Default: IGMP Snooping is d

Page 174

254EES4710BD 10 Slots L2/L3/L4 Chassis Switch 11.2.2.4 ip igmp snooping vlan static Command: ip igmp snooping vlan <vlan-id> static <

Page 175 - 7.4.1.1 clear counters

255EES4710BD 10 Slots L2/L3/L4 Chassis Switch Parameters: <vlan-id> is the VALN number specified. Command mode: Global Mode Default: IGM

Page 176 - 7.5 WEB MANAGEMENT

256EES4710BD 10 Slots L2/L3/L4 Chassis Switch Parameters: <vlan-id> is the specified VLAN number; <time-value> is maximum query resp

Page 177 - 7.5.1.2 Bandwidth control

257EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch(Config)#ip igmp snooping Switch(Config)#ip igmp snooping vlan 100 Switch(Config)#ip igmp sn

Page 178

258EES4710BD 10 Slots L2/L3/L4 Chassis Switch The configuration of Switch2 is the same as the switch in scenario 1, Switch1 takes the place of M

Page 179

25EES4710BD 10 Slots L2/L3/L4 Chassis Switch CHAPTER 19 MULTICAST PROTOCOL CONFIGURATION ... 457

Page 180

259EES4710BD 10 Slots L2/L3/L4 Chassis Switch IGMP information for VLAN 1: igmp snooping vlan status :Disabled igmp snooping vlan query

Page 181

260EES4710BD 10 Slots L2/L3/L4 Chassis Switch Displayed information Explanation igmp snooping status Whether “igmp snooping” function is enab

Page 182 - MAC 00-01-22-22-22-22

261EES4710BD 10 Slots L2/L3/L4 Chassis Switch -------------------------------------------------------------------------- Ethernet1/4 MEMBERS_P

Page 183 - 8.1.2 Forward or Filter

262EES4710BD 10 Slots L2/L3/L4 Chassis Switch command disables this debug function. Command mode: Admin Mode Default: IGMP Snooping debug is dis

Page 184 - 8.2 MAC Table Configuration

263EES4710BD 10 Slots L2/L3/L4 Chassis Switch 11.5.2 IGMP snooping configuration Click “IGMP Snooping configuration” node to enter the IGMP Sno

Page 185

264EES4710BD 10 Slots L2/L3/L4 Chassis Switch 11.5.3 IGMP snooping static multicast configuration Click “IGMP Snooping static multicast c

Page 186 - 8.4 Troubleshooting Help

265EES4710BD 10 Slots L2/L3/L4 Chassis Switch

Page 187 - 8.4.2 Troubleshooting Help

266EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 12 ACL Configuration 12.1 Introduction to ACL ACL (Access Control List) is an IP packet

Page 188 - 8.5.1 MAC Address Binding

267EES4710BD 10 Slots L2/L3/L4 Chassis Switch The following rules apply: z An access list can consist of several rules. Filtering of packets

Page 189

268EES4710BD 10 Slots L2/L3/L4 Chassis Switch access list <num> {deny | permit} {{<sIpAddr> <sMask>} | any-source | {host-so

Page 190

26EES4710BD 10 Slots L2/L3/L4 Chassis Switch 19.4.4.1.2 show ip pim interface ...

Page 191

269EES4710BD 10 Slots L2/L3/L4 Chassis Switch a. Create a name-based standard IP access list Command Explanation Global Mode ip access standa

Page 192

270EES4710BD 10 Slots L2/L3/L4 Chassis Switch [no] {deny | permit} tcp {{<sIpAddr> <sMask>} | any-source | {host-source <sIpAdd

Page 193

271EES4710BD 10 Slots L2/L3/L4 Chassis Switch ip access-group <name> {in|out } no ip access-group <name> {in|out} Applies an access

Page 194

272EES4710BD 10 Slots L2/L3/L4 Chassis Switch Default: No IP address is configured by default. Usage Guide: When the user first specifies a spec

Page 195

273EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command: firewall default {permit | deny} Function: sets firewall default action. Parameters: “p

Page 196 - 8.6 WEB MANAGEMENT

274EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command: ip access-group [<num>|<acl-name> { in|out } no ip access-group <name>

Page 197 - 8.6.1.3 MAC address query

275EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch(Config)#ip access list extended udpFlow Switch(Config-Ext-Nacl-udpFlow)#deny igmp any-sourc

Page 198

276EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch(Config-Ethernet1/10)#ip access-group 110 in Switch(Config-Ethernet1/10)#exit Switch(Config)

Page 199 - 8.6.2.2 Lock port

277EES4710BD 10 Slots L2/L3/L4 Chassis Switch Displayed information Explanation access list 10(used 0 time(s)) Numbered ACL10, reference time

Page 200 - 8.6.2.2.4 Binding MAC

278EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command mode: Admin Mode Usage Guide: Example: Switch#show firewall Firewall Status: Enable.

Page 201

27EES4710BD 10 Slots L2/L3/L4 Chassis Switch 19.6.2.2.3 ip igmp query-interval ...

Page 202 - 8.6.2.4 MAC binding debug

279EES4710BD 10 Slots L2/L3/L4 Chassis Switch 12.5.1 Numeric standard ACL configuration Click “Numeric ACL Configuration”, and then “Add Standa

Page 203 - 9.1 Introduction to VLAN

280EES4710BD 10 Slots L2/L3/L4 Chassis Switch There are several sub-sections in this category: z ACL number (100-199) z Rule - permit or de

Page 204 - 9.2 VLAN Configuration

281EES4710BD 10 Slots L2/L3/L4 Chassis Switch 12.5.4 Configure standard ACL name configuration and delete the standard ACL name configu

Page 205 - 9.2.2.1 vlan

282EES4710BD 10 Slots L2/L3/L4 Chassis Switch 12.5.5 Configure extended ACL name configuration Click “ACL name configuration”, the configurat

Page 206 - 9.2.2.2 name

283EES4710BD 10 Slots L2/L3/L4 Chassis Switch 12.5.7 ACL port binding Click “Filter configuration”, and then select “ACL port binding” to ent

Page 207 - 9.2.2.5 switchport mode

284EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 13 Port Channel Configuration 13.1 Introduction to Port Channel To understand Port Chann

Page 208

285EES4710BD 10 Slots L2/L3/L4 Chassis Switch ) All ports are in full-duplex mode. ) Ports are of the same speed. ) All ports are Access

Page 209

286EES4710BD 10 Slots L2/L3/L4 Chassis Switch 3. Enter port-channel configuration mode. Command Explanation Global Mode interface port-chan

Page 210

287EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command: port-group <port-group-number> mode {active|passive|on} no port-group <port-grou

Page 211 - 9.3 GVRP Configuration

288EES4710BD 10 Slots L2/L3/L4 Chassis Switch 13.3 Port Channel Example Scenario 1: Configuring Port Channel in LACP. Fig 14-2 Configur

Page 212 - 9.3.2.2 garp timer leave

28EES4710BD 10 Slots L2/L3/L4 Chassis Switch 19.7.6.5 Show ip pim mroute sm...

Page 213 - 9.3.2.5 gvrp

289EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch2 (Config-If-Port-Channel2)# Configuration result: Shell prompts ports aggregated successful

Page 214 - Switch C

290EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch2 (Config)#interface eth 1/6 Switch2 (Config-Ethernet1/6)#port-group 2 mode on Switch2 (Conf

Page 215

291EES4710BD 10 Slots L2/L3/L4 Chassis Switch Number of ports in group Port number in the port group Maxports Maximum number of ports allowed

Page 216 - 9.4.1.1 show vlan

292EES4710BD 10 Slots L2/L3/L4 Chassis Switch the machine state and port state of the port are as follows: mux_state: DETCH rcvm_state: P_DIS

Page 217 - 9.4.1.4 debug gvrp

293EES4710BD 10 Slots L2/L3/L4 Chassis Switch port state LACP activety . 1 LACP timeout .

Page 218 - 9.5 WEB MANAGEMENT

294EES4710BD 10 Slots L2/L3/L4 Chassis Switch Collecting Whether status of port bound status machine is “collecting” or not. Distributing W

Page 219

295EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch#debug lacp 13.4.2 Port Channel Troubleshooting Help If problems occur when configuring po

Page 220

296EES4710BD 10 Slots L2/L3/L4 Chassis Switch Apply to add the group. After finishing the group configuration, the configured port information

Page 221

297EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 14 DHCP Configuration 14.1 Introduction to DHCP DHCP [RFC2131] is the acronym for Dyna

Page 222 - 9.5.1.5 Set allow Vlan

298EES4710BD 10 Slots L2/L3/L4 Chassis Switch obtained dynamically can be different every time; manually bound IP address will be the same all t

Page 223 - 9.5.2.3 GVRP configuration

2EES4710BD 10 Slots L2/L3/L4 Chassis Switch Content CHAPTER 1 PRODUCT OVERVIEW...

Page 224 - 9.5.3.1 Show vlan

29EES4710BD 10 Slots L2/L3/L4 Chassis Switch 20.4.1.3 show aaa authenticating-user ...

Page 225 - 10.1 Introduction to MSTP

299EES4710BD 10 Slots L2/L3/L4 Chassis Switch dns-server [address1[address2[…address8]]] no dns-server Configures DNS server for DHCP clients do

Page 226 - 10.1.1 MSTP field

300EES4710BD 10 Slots L2/L3/L4 Chassis Switch client-identifier <unique-identifier> no client-identifier Specifies the unique ID of the us

Page 227 - 10.1.2 Port role

301EES4710BD 10 Slots L2/L3/L4 Chassis Switch IP address defined in “host” command to the client. Example: Specifying the IP address 10.1.128.

Page 228 - 10.2 MSTP Configuration

302EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command Mode: DHCP Address Pool Mode Usage Guide: Up to 8 DNS server addresses can be configured.

Page 229

303EES4710BD 10 Slots L2/L3/L4 Chassis Switch Function: Specifies the IP address to be assigned to the user when binding addresses manually; the

Page 230 - 10.2.2.3 instance vlan

304EES4710BD 10 Slots L2/L3/L4 Chassis Switch Function: Specifies addresses excluding from dynamic assignment; the “no ip dhcp excluded-address

Page 231 - 10.2.2.5 revision-level

305EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command: lease { [<days>] [<hours>][<minutes>] | infinite } no lease Function: S

Page 232 - 10.2.2.6 spanning-tree

306EES4710BD 10 Slots L2/L3/L4 Chassis Switch h-node that broadcasts after point-to-point communication. Example: Setting the node type for cl

Page 233

307EES4710BD 10 Slots L2/L3/L4 Chassis Switch Function: Sets the network parameter specified by the option code; the “no option <code>” co

Page 234

308EES4710BD 10 Slots L2/L3/L4 Chassis Switch Fig 14-2 DHCP relay As shown in the above figure, the DHCP client and the DHCP server are in diff

Page 235

30EES4710BD 10 Slots L2/L3/L4 Chassis Switch 21.4.1 Create VRRP Number ...

Page 236

309EES4710BD 10 Slots L2/L3/L4 Chassis Switch 4. Disable DHCP relay from forwarding DHCP broadcast packet. Command Explanation Global Mode i

Page 237

310EES4710BD 10 Slots L2/L3/L4 Chassis Switch 14.3.2.3 ip dhcp relay information policy drop Command: ip dhcp relay information policy drop no

Page 238 - 10.3 MSTP Example

311EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch(dhcp-A-config)#default-route 10.16.1.200 10.16.1.201 Switch(dhcp-A-config)#dns-server 10.

Page 239

312EES4710BD 10 Slots L2/L3/L4 Chassis Switch Scenario 2: Fig 14-3 DHCP Relay Configuration As shown in the above figure, ES4710BD is configu

Page 240

313EES4710BD 10 Slots L2/L3/L4 Chassis Switch client will be requesting the IP address in the same segment of the VLAN interface after VLAN inte

Page 241

314EES4710BD 10 Slots L2/L3/L4 Chassis Switch conflicting for use. The “Clear ip dhcp conflict” command can be used to delete the conflict recor

Page 242 - 10.4.1.1 show spanning-tree

315EES4710BD 10 Slots L2/L3/L4 Chassis Switch Type Type of assignment: manual binding or dynamic assignment. 14.5.1.5 show ip dhcp conflict C

Page 243

316EES4710BD 10 Slots L2/L3/L4 Chassis Switch BOOTREPLY 1911 DHCPOFFER 6 DHCPACK 6 DHCPNAK 0 DHCPRELAY 1907 DHCPFORWARD 0 Switch# Displayed info

Page 244

317EES4710BD 10 Slots L2/L3/L4 Chassis Switch 14.5.2 DHCP Troubleshooting Help If the DHCP clients cannot obtain IP addresses and other network

Page 245 - 10.4.1.3 show mst-pending

318EES4710BD 10 Slots L2/L3/L4 Chassis Switch 14.6.2.1 Address pool configuration Click “DHCP configuration”, “DHCP server configuration”, “A

Page 246

31EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 1 Product Overview RECOMMENDATION: Please read this manual first before using the swit

Page 247 - 10.5 WEB MANAGEMENT

319EES4710BD 10 Slots L2/L3/L4 Chassis Switch 14.6.2.2 Client’s default gateway configuration Click “DHCP configuration”, “DHCP server conf

Page 248 - 10.5.2 MSTP port operation

320EES4710BD 10 Slots L2/L3/L4 Chassis Switch 14.6.2.4 Client wins server configuration Click DHCP configuration, DHCP server configuration,

Page 249 - 10.5.3 MSTP global control

321EES4710BD 10 Slots L2/L3/L4 Chassis Switch configuration” to configure the DHCP client boot file name and client server address which is for

Page 250 - MSTP field

322EES4710BD 10 Slots L2/L3/L4 Chassis Switch 14.6.2.7 Manual address pool configuration Click “DHCP configuration”, “DHCP server configurat

Page 251 - 10.5.4 Show MSTP setting

323EES4710BD 10 Slots L2/L3/L4 Chassis Switch 14.6.2.9 DHCP packet statistics Click “DHCP configuration”, “DHCP server configuration”, “DHCP

Page 252

324EES4710BD 10 Slots L2/L3/L4 Chassis Switch Click “DHCP configuration”, “DHCP relay configuration”, “DHCP relay configuration” to configure th

Page 253 - 11.2.2.1 ip igmp snooping

325EES4710BD 10 Slots L2/L3/L4 Chassis Switch 14.6.4.2 Delete conflict log Click “DHCP configuration”, “DHCP debugging” to delete conflicti

Page 254

326EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 15 SNTP Configuration The Network Time Protocol (NTP) is widely used for clock synchr

Page 255

327EES4710BD 10 Slots L2/L3/L4 Chassis Switch 15.1 SNTP Configuration Commands 15.1.1 sntp server Command: sntp server <server_address>

Page 256

328EES4710BD 10 Slots L2/L3/L4 Chassis Switch Default: The default time difference setting is “add 8”. Command mode: Global Mode Example: Sett

Page 257 - 11.3 IGMP Snooping Example

32EES4710BD 10 Slots L2/L3/L4 Chassis Switch 1.1.2 Features  Advanced Architecture The design for the ES4710BD core routing switch is fully di

Page 258 - Swi t c h 2

329EES4710BD 10 Slots L2/L3/L4 Chassis Switch 15.3 SNTP Troubleshooting Help 15.3.1 Monitor and Debug Commands 15.3.1.1 show sntp Command: s

Page 259 - Switch#show ip igmp snooping

330EES4710BD 10 Slots L2/L3/L4 Chassis Switch 15.4.2 Request interval configuration Click “SNTP configuration”, “Request interval configurati

Page 260

331EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 16 QoS Configuration 16.1 Introduction to QoS QoS (Quality of Service) is a set of capab

Page 261

332EES4710BD 10 Slots L2/L3/L4 Chassis Switch Robin). In Profile: Traffic within the QoS policy range (bandwidth or burst value) is called “In

Page 262

333EES4710BD 10 Slots L2/L3/L4 Chassis Switch Fig 16-3 Basic QoS Model Classification: Classifies traffic according to packet classification

Page 263 - 11.5 WEB MANAGEMENT

334EES4710BD 10 Slots L2/L3/L4 Chassis Switch Fig 16-4 Classification process Policing and remark: Each packet in classified ingress traffic i

Page 264

335EES4710BD 10 Slots L2/L3/L4 Chassis Switch Fig 16-5 Policing and Remarking process Queuing and scheduling: Packets at the egress will re-m

Page 265

336EES4710BD 10 Slots L2/L3/L4 Chassis Switch Fig 16-6 Queuing and Scheduling process 16.2 QoS Configuration 16.2.1 QoS Configuration Task

Page 266

337EES4710BD 10 Slots L2/L3/L4 Chassis Switch Set up a classification rule according to ACL, VLAN ID, IP Precedence or DSCP to classify the

Page 267 - 12.1 Introduction to ACL

338EES4710BD 10 Slots L2/L3/L4 Chassis Switch policy-map <policy-map-name> no policy-map <policy-map-name> Creates a policy map and

Page 268 - 12.2 ACL configuration

33EES4710BD 10 Slots L2/L3/L4 Chassis Switch  Layer 3 Forwarding Layer 3 forwarding is the forwarding of Layer 3 packets (IP packet) across VL

Page 269

339EES4710BD 10 Slots L2/L3/L4 Chassis Switch priority <cos>] no mls qos trust disables the current trust status of the port. mls qos co

Page 270

340EES4710BD 10 Slots L2/L3/L4 Chassis Switch <dscp-mutation-name> <in-dscp> to <out-dscp> |ip-prec-dscp <dscp1...dscp8>

Page 271

341EES4710BD 10 Slots L2/L3/L4 Chassis Switch Function: Configures the matching criterion in the class map; the “no match {access-group | ip dsc

Page 272

342EES4710BD 10 Slots L2/L3/L4 Chassis Switch Parameters: < class-map-name> is the class map name used by the class. Default: No policy

Page 273 - 12.2.2.4 firewall default

343EES4710BD 10 Slots L2/L3/L4 Chassis Switch according to policed-dscp mapping when specified speed is exceeded. Default: There is no policy

Page 274 - 12.2.2.7 ip access-group

344EES4710BD 10 Slots L2/L3/L4 Chassis Switch 16.2.2.9 police aggregate Command: police aggregate <aggregate-policer-name> no police agg

Page 275

345EES4710BD 10 Slots L2/L3/L4 Chassis Switch Example: Configuring Ethernet port 1/1 to trust CoS value, i.e., classifying the packets according

Page 276 - 12.3 ACL Example

346EES4710BD 10 Slots L2/L3/L4 Chassis Switch 16.2.2.13 mls qos dscp-mutation Command: mls qos dscp-mutation <dscp-mutation-name> no mls

Page 277 - 12.4.1.1 show access lists

347EES4710BD 10 Slots L2/L3/L4 Chassis Switch Function: Configures the queue out mode. The “no priority-queue out” command restores the default

Page 278 - 12.4.1.3 show firewall

348EES4710BD 10 Slots L2/L3/L4 Chassis Switch <dscp1...dscp8> are the 8 DSCP value corresponding to the 0 to 7 CoS value, each DSCP value

Page 279 - 12.5 WEB MANAGEMENT

34EES4710BD 10 Slots L2/L3/L4 Chassis Switch  IGMP Snooping ES4710BD supports IGMP Snooping based on multi-casting applications enabling vario

Page 280

349EES4710BD 10 Slots L2/L3/L4 Chassis Switch the port in trust CoS mode without changing DSCP value, and set the default CoS value of the port

Page 281

350EES4710BD 10 Slots L2/L3/L4 Chassis Switch An ACL name 1 is set to matching segment 192.168.1.0. QoS was enabled globally, a class map named

Page 282

351EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch(Config-ClassMap)# exit Switch(Config)#policy-map p1 Switch(Config-PolicyMap)#class c1 Switc

Page 283

352EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command mode: Admin Mode Usage Guide: Example: Switch #show mls qos aggregate-policer policer1

Page 284 - 12.5.7 ACL port binding

353EES4710BD 10 Slots L2/L3/L4 Chassis Switch 0x200 0x200 0x200 0x200 0x200 0x200 0x200 0x200 Displayed information Explan

Page 285 - Fig 14-1 Port aggregation

354EES4710BD 10 Slots L2/L3/L4 Chassis Switch out-profile Total out-profile data packets match this class map. 16.4.1.4 show mls qos maps Comm

Page 286

355EES4710BD 10 Slots L2/L3/L4 Chassis Switch Policed-dscp map: d1 : d2 0 1 2 3 4 5 6 7 8 9 0: 0 1 2 3 4 5 6 7

Page 287 - 13.2.2.2 port-group mode

356EES4710BD 10 Slots L2/L3/L4 Chassis Switch Policy Map p1 Class Map name: c1 police 16000000 2000 exceed-action drop Displayed info

Page 288

357EES4710BD 10 Slots L2/L3/L4 Chassis Switch z QoS status-Close or Open. To enable QoS, select Open, then click Apply. 16.5.2 Class-map con

Page 289 - 13.3 Port Channel Example

358EES4710BD 10 Slots L2/L3/L4 Chassis Switch Match value 1, select set to Operation type, and then click Apply. 16.5.3 Policy-map priority co

Page 290

35EES4710BD 10 Slots L2/L3/L4 Chassis Switch  Restart and reset to factory setting can be done both locally and remotely  TFTP /FTP firmware

Page 291 - 13.4.1.1 show port-group

359EES4710BD 10 Slots L2/L3/L4 Chassis Switch 16.5.3.2 Policy-map priority configuration Click “Policy-map priority configuration” to entry con

Page 292

360EES4710BD 10 Slots L2/L3/L4 Chassis Switch 16.5.3.4 Add/Remove aggregate policy Click Add/Remove aggregate policer to entry configure page.

Page 293

361EES4710BD 10 Slots L2/L3/L4 Chassis Switch Example: Apply the aggregate policer agg1 by c1 class-map, input the graphic presentation value, a

Page 294

362EES4710BD 10 Slots L2/L3/L4 Chassis Switch 16.5.4.2 Port default CoS configuration Click “Port default CoS configuration” to entry configure

Page 295 - 13.4.1.2 debug lacp

363EES4710BD 10 Slots L2/L3/L4 Chassis Switch z Port name z DSCP mutation name z Operation-Set or Remove Example: Set the DSCP mutation in Et

Page 296 - 13.5 WEB MANAGEMENT

364EES4710BD 10 Slots L2/L3/L4 Chassis Switch 16.5.5.2 Egress-queue Work mode configuration Click “Egress-queue work mode configuration” to en

Page 297

365EES4710BD 10 Slots L2/L3/L4 Chassis Switch 16.5.6 QoS mapping configuration Click “QoS mapping configuration” to display extensions, incl

Page 298 - 14.1 Introduction to DHCP

366EES4710BD 10 Slots L2/L3/L4 Chassis Switch 16.5.6.2 DSCP-to-CoS mapping Click “DSCP-to-CoS mapping” to entry configure page. Terms are descri

Page 299

367EES4710BD 10 Slots L2/L3/L4 Chassis Switch 16.5.6.4 IP-precedence-to-DSCP mapping Click “IP-Precedence-to-DSCP mapping” to enter the configu

Page 300

368EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 17 L3 Forward Configuration ES4710BD supports Layer 3 forwarding which forwards Layer 3 pr

Page 301 - 14.2.2.2 client-identifier

36EES4710BD 10 Slots L2/L3/L4 Chassis Switch 1.3 Physical Specifications  Management Port □ One RJ-45 serial port for each management modul

Page 302 - 14.2.2.5 dns-server

369EES4710BD 10 Slots L2/L3/L4 Chassis Switch <vlan-id>” command deletes the VLAN interface (Layer 3 interface) created in the switch. 1

Page 303 - 14.2.2.8 host

370EES4710BD 10 Slots L2/L3/L4 Chassis Switch no ip fib optimize aggregation algorithm; the “no ip fib optimize” disables the optimized IP route

Page 304

371EES4710BD 10 Slots L2/L3/L4 Chassis Switch 0 fragmented, 0 couldn't fragment, 0 fragment sent Sent: 0 generated, 0

Page 305 - 14.2.2.13 lease

372EES4710BD 10 Slots L2/L3/L4 Chassis Switch and packets without route. ICMP statistics: ICMP packet statistics. Rcvd: 0 total 0 errors

Page 306 - 14.2.2.15 netbios-node-type

373EES4710BD 10 Slots L2/L3/L4 Chassis Switch ES4710BD supports the configuration of proxy ARP for some applications. For instance, when an ARP

Page 307 - 14.2.2.18 option

374EES4710BD 10 Slots L2/L3/L4 Chassis Switch 17.3.2.2.2 ip proxy-arp Command: ip proxy-arp no ip proxy-arp Function: Enables proxy ARP for VLAN

Page 308 - 14.2.2.19 service dhcp

375EES4710BD 10 Slots L2/L3/L4 Chassis Switch 50.1.1.9 00-00-00-00-00-09 Vlan50 Ethernet1/1 Static 150.1.1.2 00-00-58

Page 309

376EES4710BD 10 Slots L2/L3/L4 Chassis Switch 17.3.3.2 ARP Troubleshooting Help If ping from the switch to directly connected network devices f

Page 310 - 14.3.2.2 ip helper-address

377EES4710BD 10 Slots L2/L3/L4 Chassis Switch configuration. 17.4.3.1 Configure static ARP Click “ARP configuration” to configure static ARP. Eq

Page 311

378EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 18 Routing Protocol Configuration To communicate with a remote host over the Internet, a

Page 312

37EES4710BD 10 Slots L2/L3/L4 Chassis Switch a grounding post has been provided on each side of the rack for grounding connections. In addition,

Page 313

379EES4710BD 10 Slots L2/L3/L4 Chassis Switch The route table mainly consists of the following: z Destination address: used to identify the d

Page 314

380EES4710BD 10 Slots L2/L3/L4 Chassis Switch priority according to the priority of routing protocols. At same time, static routes can be introd

Page 315

381EES4710BD 10 Slots L2/L3/L4 Chassis Switch [<preference>]” command deletes a static route entry. Parameters: <ip-address> and

Page 316

382EES4710BD 10 Slots L2/L3/L4 Chassis Switch Destination Mask Nexthop Interface Pref C 2.2.2.0 255.255.25

Page 317

383EES4710BD 10 Slots L2/L3/L4 Chassis Switch SWITCH-2PC1£º10.1.1.2PC2£º10.1.4.2PC3£º10.1.5.2vlan3£º10.1.5.1vlan1£º10.1.1.1vlan2£º10.1.2.1 vlan

Page 318 - 14.6 Web management

384EES4710BD 10 Slots L2/L3/L4 Chassis Switch Uses the “show ip route” command to display the information about static route in the route table:

Page 319

385EES4710BD 10 Slots L2/L3/L4 Chassis Switch switch will be selected with the metrics increasing progressively. This greatly affects the route

Page 320

386EES4710BD 10 Slots L2/L3/L4 Chassis Switch 18.3.2 RIP Configuration 18.3.2.1 RIP Configuration Task Sequence 1. Enable RIP (required) (1)

Page 321

387EES4710BD 10 Slots L2/L3/L4 Chassis Switch (1) Configure RIP sending mechanism a. Configure regular RIP packets transmission b. Configure RIP

Page 322

388EES4710BD 10 Slots L2/L3/L4 Chassis Switch ip rip authentication mode {text| md5 type {cisco|usual}} no ip rip authentication mode Sets the

Page 323

38EES4710BD 10 Slots L2/L3/L4 Chassis Switch the panel as RUN) are provided for each board. On the Main Control cards there is Master-Slave indi

Page 324

389EES4710BD 10 Slots L2/L3/L4 Chassis Switch ip rip receive version {v1 | v2 | v12} no ip rip receive version Sets the version of RIP packets

Page 325 - 14.6.4.1 Delete binding log

390EES4710BD 10 Slots L2/L3/L4 Chassis Switch z show ip rip z debug ip rip packet z debug ip rip recv z debug ip rip send 18.3.2.2.1 auto-s

Page 326

391EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command: ip rip authentication key-chain <name-of-chain> no ip rip authentication

Page 327

392EES4710BD 10 Slots L2/L3/L4 Chassis Switch 18.3.2.2.6 ip rip metricout Command: ip rip metricout <value> no ip rip metricout Function:

Page 328 - 15.1.3 sntp timezone

393EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command: ip rip receive version {v1 | v2 | v12} no ip rip receive version Function: Configure t

Page 329 - SNTP/NTP

394EES4710BD 10 Slots L2/L3/L4 Chassis Switch Usage Guide: Sets split horizon to prevent routing loops, i.e., prevent layer 3 switches from broa

Page 330 - 15.4 WEB MANAGEMENT

395EES4710BD 10 Slots L2/L3/L4 Chassis Switch Default: Zero fields are check in RIP-I packets by default. Command mode: RIP configuration mode

Page 331 - 15.4.4 Show SNMP

396EES4710BD 10 Slots L2/L3/L4 Chassis Switch Function: Adjusts the time of RIP timers for update, expire, and hold down; the “no timer basic” c

Page 332 - 16.1 Introduction to QoS

397EES4710BD 10 Slots L2/L3/L4 Chassis Switch Usage Guide: The user can decide whether the routing protocols configured are correct and perform

Page 333 - 16.1.3 Basic QoS Model

398EES4710BD 10 Slots L2/L3/L4 Chassis Switch default metric 16 neighbour is preference is 100 Displayed information Explanation rip is turning

Page 334 - Fig 16-3 Basic QoS Model

3EES4710BD 10 Slots L2/L3/L4 Chassis Switch 1.4.2.4 EM4700BD-2XG-XENPAK ...

Page 335

39EES4710BD 10 Slots L2/L3/L4 Chassis Switch z 12 fiber Gb ports line card (EM4700BD-12GX-SFP): supporting 12 SFP Gb fiber ports for layer 2 an

Page 336 - Remark packet DSCP according

399EES4710BD 10 Slots L2/L3/L4 Chassis Switch received a rip packet from 159.226.42.1 rip packet cmd : 2 version:1 18.3.2.2.23 debug

Page 337 - 16.2 QoS Configuration

400EES4710BD 10 Slots L2/L3/L4 Chassis Switch 00:02:50: start at 170********************* send packets to 11.11.11.2 packet header: cmd

Page 338

401EES4710BD 10 Slots L2/L3/L4 Chassis Switch (10.1.1.2) only, update information is not exchanged between switchA and switchC vlan2 (20.1.1.2).

Page 339

402EES4710BD 10 Slots L2/L3/L4 Chassis Switch SwitchC#config SwitchC(Config)# interface vlan 2 SwitchC(Config-If-vlan2)# ip address 20.1.1.2 255

Page 340

403EES4710BD 10 Slots L2/L3/L4 Chassis Switch Automatic network summarization is not in effect Disable RIP auto aggregation default metric for r

Page 341 - 16.2.2.3 match

404EES4710BD 10 Slots L2/L3/L4 Chassis Switch default metric for redistribute is : RIP protocol default metric value. neigbour is: The neigh

Page 342 - 16.2.2.5 class

405EES4710BD 10 Slots L2/L3/L4 Chassis Switch • State of the connecting link Link-state information is flooded throughout the network so that al

Page 343 - 16.2.2.7 police

406EES4710BD 10 Slots L2/L3/L4 Chassis Switch exchange link-state information with the other OSPF layer 3 switches to formal a link-state databa

Page 344

407EES4710BD 10 Slots L2/L3/L4 Chassis Switch 1) Each OSPF-enabled layer 3 switch maintains a database (LS database) describing the link-state

Page 345 - 16.2.2.10 mls qos trust

408EES4710BD 10 Slots L2/L3/L4 Chassis Switch (3) Configure other OSPF protocol parameters a. Configure OSPF routing protocol priority b. Conf

Page 346 - 16.2.2.12 service-policy

40EES4710BD 10 Slots L2/L3/L4 Chassis Switch Off Cards are powered off and can be removed On (Green) Master Master-Slave indicator M/S Off Sl

Page 347 - 16.2.2.15 priority-queue out

409EES4710BD 10 Slots L2/L3/L4 Chassis Switch d. Configure OSPF packet sending timer parameter (timer of broadcast interface sending HELLO packe

Page 348 - 16.2.2.17 mls qos map

410EES4710BD 10 Slots L2/L3/L4 Chassis Switch (3) Configure other OSPF protocol parameters a. Configure OSPF routing protocol priority b. Conf

Page 349 - 16.3 QoS Example

411EES4710BD 10 Slots L2/L3/L4 Chassis Switch z ip opsf dead-interval z ip ospf enable area z ip ospf hello-interval z ip ospf passive-inter

Page 350 - SWITCH#CONFIG

412EES4710BD 10 Slots L2/L3/L4 Chassis Switch 18.4.2.2.2 default redistribute interval Command: default redistribute interval <time> no d

Page 351

413EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch(Config-Router-Ospf)#default redistribute tag 20000 18.4.2.2.5 default redistribute type

Page 352 - 16.4.1.1 show mls-qos

414EES4710BD 10 Slots L2/L3/L4 Chassis Switch Example: Setting the OSPF route cost of interface vlan1 to 3. Switch(Config-If-Vlan1)#ip ospf co

Page 353

415EES4710BD 10 Slots L2/L3/L4 Chassis Switch Default: The default HELLO-packet-sending interval is 10 seconds. Command mode: Interface Mode

Page 354

416EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch(Config-If-Vlan1)#ip ospf priority 0 18.4.2.2.13 ip ospf retransmit-interval Command: ip o

Page 355 - 16.4.1.4 show mls qos maps

417EES4710BD 10 Slots L2/L3/L4 Chassis Switch Parameters: <network> and <mask> are the network IP address and mask in decimal forma

Page 356 - 16.4.1.6 show policy-map

418EES4710BD 10 Slots L2/L3/L4 Chassis Switch respectively; tag specifies the tag of the routes, <tag> is the tag value for the routes,

Page 357 - 16.5 WEB MANAGEMENT

41EES4710BD 10 Slots L2/L3/L4 Chassis Switch Property Specification Connector RJ-45 (Receptacle) Connector type z 10/100Mbps auto sensing z C

Page 358

419EES4710BD 10 Slots L2/L3/L4 Chassis Switch 18.4.2.2.20 stub cost Command: stub cost <cost> area <area_id > no stub area <area

Page 359

420EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command: show ip ospf Function: Displays major OSPF information. Default: Nothing displayed

Page 360

421EES4710BD 10 Slots L2/L3/L4 Chassis Switch Destination AdvRouter NextHop Age SeqNumber Type Cost 10.1.1.125 11.11.1.2 11.1.1.2

Page 361

422EES4710BD 10 Slots L2/L3/L4 Chassis Switch DB entry count 6 LS_RTR 3 LS_NET 3 LS_SUM_NET 1 LS_SUM_ASB 0 LS_ASE 3 AS internal route 4

Page 362 - 16.5.4 Apply QoS to port

423EES4710BD 10 Slots L2/L3/L4 Chassis Switch (Net's IP) 11.11.1.0 11.11.4.1 0 2147483656 1 6777215 11.

Page 363

424EES4710BD 10 Slots L2/L3/L4 Chassis Switch OSPF router ID The ID of the layer 3 switch. Area 1>>>>>>>> Area ID: 0

Page 364

425EES4710BD 10 Slots L2/L3/L4 Chassis Switch Authentication key OSPF packet authentication key Timer Hell, Poll, Dea, Retrans OSPF protocol

Page 365

426EES4710BD 10 Slots L2/L3/L4 Chassis Switch router ip addr IP address of the interface in the neighboring layer 3 switch state Link-state sta

Page 366 - 16.5.6.1 CoS-to-DSCP mapping

427EES4710BD 10 Slots L2/L3/L4 Chassis Switch Function: Displays OSPF virtual link information. Default: Nothing displayed by default Comm

Page 367 - 16.5.6.2 DSCP-to-CoS mapping

428EES4710BD 10 Slots L2/L3/L4 Chassis Switch protocol 18.4.2.2.31 debug ip ospf event Command: debug ip ospf event no debug ip ospf event

Page 368

42EES4710BD 10 Slots L2/L3/L4 Chassis Switch On (Green, blinks at 8 Hz) System is loading (Booting after card hot swapping) On (Yellow, blinks a

Page 369 - 17.1 Layer 3 Interface

429EES4710BD 10 Slots L2/L3/L4 Chassis Switch 02:40:58: receive a HELLO packet from 11.11.4.2 via Broadcast interface 11.11.4.1 02:40:58: 18.4.2

Page 370 - 17.2 IP Forwarding

430EES4710BD 10 Slots L2/L3/L4 Chassis Switch ! Configuration of the IP address for interface vlan2 Switch1(Config)# interface vlan 2 Switch1(Co

Page 371 - 17.2.3.1.1 show ip traffic

431EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch3#config Switch3(Config)# interface vlan 3 Switch3(Config-if-vlan1)# ip address 20.1.1.2 255

Page 372

432EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch5(Config-if-vlan3)#exit !Enable OSPF protocol, configure the number of the area in which int

Page 373 - 17.3 ARP

433EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch11 are edge layer 3 switches of the area, Switch5 and Switch7 are edge layer 3 switches of t

Page 374 - 17.3.2 ARP configuration

434EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch1(Config-If-Vlan2)#exit !Enable OSPF protocol, configure the area number for interface vlan2

Page 375 - 17.3.3.1.1 show arp

435EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch3(Config-If-Vlan2)#exit !Enable OSPF protocol, configure the area number for interface vlan2

Page 376 - 17.3.3.1.3 debug arp

436EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch4(Config-If-Vlan1)# ip address 10.1.6.1 255.255.255.0 Switch4(Config-If-Vlan1)#ip ospf enabl

Page 377 - 17.4 Web management

437EES4710BD 10 Slots L2/L3/L4 Chassis Switch (1)show ip ospf Example: Switch#show ip ospf my router ID is 11.11.4.1 preference=10 ase perfer

Page 378 - 17.4.3.3 Show ARP

438EES4710BD 10 Slots L2/L3/L4 Chassis Switch A 5.1.2.0 255.255.255.0 12.1.1.2 Vlan12 150 A 5.1.3.0 255

Page 379 - 18.1 Route Table

43EES4710BD 10 Slots L2/L3/L4 Chassis Switch Fig 1-5 EM4700BD-12GX-SFP Front Panel view 1.4.2.3.2 Front Panel - Indicator The following

Page 380 - 18.2 Static Route

439EES4710BD 10 Slots L2/L3/L4 Chassis Switch type in out HELLO 1048 253 DD 338 337 LS Req 62 219

Page 381 - 18.2.3.2.1 ip route

440EES4710BD 10 Slots L2/L3/L4 Chassis Switch 11.11.4.2 11.11.4.2 18 2147483863 1 6777215 Router LSA 11.11.4

Page 382 - 18.2.3.2.2 show ip route

441EES4710BD 10 Slots L2/L3/L4 Chassis Switch 11.11.1.3 14.14.14.1 15 2147483705 1 53384

Page 383

442EES4710BD 10 Slots L2/L3/L4 Chassis Switch cost Cost value State Status Type Layer 3 switch type, such as designated Priority Configure

Page 384 - 18.2.5 Troubleshooting Help

443EES4710BD 10 Slots L2/L3/L4 Chassis Switch area id The id of the area for the interface router id The ID of the neighbor layer 3 switch

Page 385 - 18.3 RIP

444EES4710BD 10 Slots L2/L3/L4 Chassis Switch my router ID is 100.1.1.1 preference=10 ase perference=150 export metric=1 export tag=-214748364

Page 386

445EES4710BD 10 Slots L2/L3/L4 Chassis Switch 18.5 WEB MANAGEMENT Click “Route configuration” to open “routing protocol configuration” to co

Page 387 - 18.3.2 RIP Configuration

446EES4710BD 10 Slots L2/L3/L4 Chassis Switch Click RIP configuration to open RIP configuration including: z Enable RIP: enable RIP including

Page 388

447EES4710BD 10 Slots L2/L3/L4 Chassis Switch z Redistribute imported route cost z Operation type: Add or Remove Example: For protocol select

Page 389

448EES4710BD 10 Slots L2/L3/L4 Chassis Switch 18.3.2.2.3 z RIP authentication type: sets up RIP authentication type. Text means text authentica

Page 390

44EES4710BD 10 Slots L2/L3/L4 Chassis Switch Table 1.7 EM4700BD-12GX-SFP port description Port Type Specification SFP z SFP-SX transceiver:

Page 391 - 18.3.2.2.2 default-metric

449EES4710BD 10 Slots L2/L3/L4 Chassis Switch 18.5.2.2.5 Set RIP timer Click “RIP timer configuration” to enter the configuration page. Equiva

Page 392 - 18.3.2.2.5 ip rip metricin

450EES4710BD 10 Slots L2/L3/L4 Chassis Switch Click “OSPF enable” to enter the configuration page. Equivalent to CLI command 18.4.2.2.19. z OSP

Page 393 - 18.3.2.2.8 ip rip output

451EES4710BD 10 Slots L2/L3/L4 Chassis Switch 18.5.3.1.4 Configure OSPF area for port Click “OSPF area configuration” to enter the configurati

Page 394 - 18.3.2.2.12 ip split-horizon

452EES4710BD 10 Slots L2/L3/L4 Chassis Switch 18.5.3.2.2 Passive interface configuration Click “Passive interface configuration” to enter the

Page 395 - 18.3.2.2.15 rip checkzero

453EES4710BD 10 Slots L2/L3/L4 Chassis Switch 18.5.3.3 OSPF imported route parameter configuration Click “OSPF Imported route parameter config

Page 396 - 18.3.2.2.18 timer basic

454EES4710BD 10 Slots L2/L3/L4 Chassis Switch z Reset: resets each column value to default in this page and this action will not change setting

Page 397 - 18.3.2.2.19 version

455EES4710BD 10 Slots L2/L3/L4 Chassis Switch 18.5.3.4.3 OSPF virtual link configuration Click “OSPF virtual link configuration” to enter the

Page 398 - 18.3.2.2.21 show ip rip

456EES4710BD 10 Slots L2/L3/L4 Chassis Switch z show ip ospf cumulative: displays OSPF statistic information. Equivalent to CLI command 18.4.2.

Page 399

457EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 19 Multicast protocol Configuration 19.1 Multicast Protocol Overview 19.1.1 Introducti

Page 400

458EES4710BD 10 Slots L2/L3/L4 Chassis Switch group at any time. A multicast group can be either a perpetual one or temporary one. Part of mul

Page 401 - 18.3.3 Typical RIP Scenario

45EES4710BD 10 Slots L2/L3/L4 Chassis Switch 1.4.2.4.2 Front Panel - Indicator The following table describes the front panel indicators for t

Page 402

459EES4710BD 10 Slots L2/L3/L4 Chassis Switch multicast group address in the destination address field of the IP packet. The multicast model dif

Page 403

460EES4710BD 10 Slots L2/L3/L4 Chassis Switch Function: Displays the IP multicast packet forwarding entries. Parameters: [group_address] specifi

Page 404

461EES4710BD 10 Slots L2/L3/L4 Chassis Switch 19.3 PIM-DM 19.3.1 Introduction to PIM-DM PIM-DM (Protocol Independent Multicast,Dense Mode) is

Page 405 - 18.4 OSPF

462EES4710BD 10 Slots L2/L3/L4 Chassis Switch If a pruned downstream node needs to restore to the forwarding state, the node will send a graft p

Page 406

463EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command: ip pim dense-mode no ip pim dense-mode Function: Enables PIM-DM protocol on the interface

Page 407

464EES4710BD 10 Slots L2/L3/L4 Chassis Switch SWITCHASWITCHBEt her net 1/ 1vl an2Et her net 1/ 1vl an1Et her net 1/ 2vl an2Et her net 1/ 2vl an

Page 408 - 18.4.2 OSPF Configuration

465EES4710BD 10 Slots L2/L3/L4 Chassis Switch debug ip pim Enables the debugging function for displaying detailed PIM information; the “no” for

Page 409

466EES4710BD 10 Slots L2/L3/L4 Chassis Switch Outgoing interface list Outgoing interface list. Prune interface list Downstream prune interfa

Page 410

467EES4710BD 10 Slots L2/L3/L4 Chassis Switch 2.1.1.1 Vlan1 00:26:23 00:01:39 Switch# Displayed information Explanation Int

Page 411

468EES4710BD 10 Slots L2/L3/L4 Chassis Switch information to Edge-Core technical service center. 19.4 PIM-SM 19.4.1 Introduction to PIM-SM P

Page 412

46EES4710BD 10 Slots L2/L3/L4 Chassis Switch 1.4.2.4.5 Front Panel – SWAP Button The EM4700BD-2XG-XENPAK provides a SWAP button for hot swappin

Page 413

469EES4710BD 10 Slots L2/L3/L4 Chassis Switch On receiving BSR advertised C-RP messages, multicast routers will calculate the RP corresponding t

Page 414 - 18.4.2.2.7 ip ospf cost

470EES4710BD 10 Slots L2/L3/L4 Chassis Switch 1) Configure a switch as the candidate BSR. Command Explanation Interface Mode ip pim bsr-can

Page 415 - 18.4.2.2.9 ospf enable area

471EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command: ip pim sparse-mode no ip pim sparse-mode Function: Enables PIM-SM protocol on the interfa

Page 416

472EES4710BD 10 Slots L2/L3/L4 Chassis Switch specified period, that neighbor is considered to be lost. This time setting must be no greater tha

Page 417 - 18.4.2.2.15 network

473EES4710BD 10 Slots L2/L3/L4 Chassis Switch this command is configured. Example: Setting the interface vlan1 as the candidate RP announcing

Page 418 - 18.4.2.2.16 preference

474EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch (Config)#interface vlan 2 Switch(Config-If-Vlan2)# ip pim sparse-mode Switch(Config-If-Vlan

Page 419 - 18.4.2.2.19 router ospf

475EES4710BD 10 Slots L2/L3/L4 Chassis Switch PIMv2 Bootstrap information BSR address: 192.4.1.3 Priority: 192, Hash mask length: 30 E

Page 420 - 18.4.2.2.22 show ip ospf

476EES4710BD 10 Slots L2/L3/L4 Chassis Switch Expires The remaining time before considering the neighbor to be invalid. 19.4.4.1.3 show ip

Page 421

477EES4710BD 10 Slots L2/L3/L4 Chassis Switch 192.2.1.1 Vlan2 31 00:11:39 00:01:16 / 192.4.1.4 Vlan4 33

Page 422

478EES4710BD 10 Slots L2/L3/L4 Chassis Switch 00:17:52: PIM: Received v2 Join/Prune on Vlan2 from 192.3.1.3 to 192.3.1.2 00:17:52: PIM: Receive

Page 423

47EES4710BD 10 Slots L2/L3/L4 Chassis Switch 1.4.2.5.2 Front Panel - Indicator The following table describes the front panel indicators for EM

Page 424

479EES4710BD 10 Slots L2/L3/L4 Chassis Switch correctness must be ensured.  PIM-SM protocol requires the support of RP and BSR. So “show ip

Page 425

480EES4710BD 10 Slots L2/L3/L4 Chassis Switch information, they know the route metric for each other to get to the source network, and the switc

Page 426

481EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command Explanation Interface Mode [no] ip dvmrp enable Enable DVMRP; the “no ip dvmrp enable” c

Page 427

482EES4710BD 10 Slots L2/L3/L4 Chassis Switch ip dvmrp report-interval <time_val> no ip dvmrp report-interval Sets the interval for sendin

Page 428

483EES4710BD 10 Slots L2/L3/L4 Chassis Switch 19.5.2.2.1 ip dvmrp cisco-compatible Command: ip dvmrp cisco-compatible <A.B.C.D> no ip

Page 429

484EES4710BD 10 Slots L2/L3/L4 Chassis Switch Usage Guide: If a new receiver joins that interface when an interface is in the pruned state, the

Page 430

485EES4710BD 10 Slots L2/L3/L4 Chassis Switch 19.5.2.2.6 ip dvmrp probe-interval Command: ip dvmrp probe-interval <time_val> no ip d

Page 431

486EES4710BD 10 Slots L2/L3/L4 Chassis Switch Parameters: < time_val> is the time to timeout a route, the valid range is 20 to 1400 second

Page 432

487EES4710BD 10 Slots L2/L3/L4 Chassis Switch Fig 19-3 DVMRP network topology The followings are the configurations of SwitchA and SwitchB. (

Page 433

488EES4710BD 10 Slots L2/L3/L4 Chassis Switch Outgoing interface list: (Vlan2), protos: 0x2 Upstream prune interface list: Downst

Page 434

48EES4710BD 10 Slots L2/L3/L4 Chassis Switch Table 1.10 EM-7600-ES-2GB port description Port Type Specification SFP z SFP-SX transceiver:

Page 435

489EES4710BD 10 Slots L2/L3/L4 Chassis Switch Command mode: Admin Mode Usage Guide: This command is used to display DVMRP route table entries; D

Page 436

490EES4710BD 10 Slots L2/L3/L4 Chassis Switch 19.5.4.1.5 debug ip dvmrp detail Command: debug ip dvmrp detail Function: Enables the debug fu

Page 437

491EES4710BD 10 Slots L2/L3/L4 Chassis Switch DVMRP pruning debug is on 02:22:20:26: DVMRP: Received prune on vlan2 from 105.1.1.2, len 20 02:22

Page 438

492EES4710BD 10 Slots L2/L3/L4 Chassis Switch network segments connecting to its interfaces. As to the hosts, they only need to keep the informa

Page 439

493EES4710BD 10 Slots L2/L3/L4 Chassis Switch b. Configure maximum response time for IGMP queries c. Configure timeout setting for IGMP queries

Page 440

494EES4710BD 10 Slots L2/L3/L4 Chassis Switch ip igmp static-group <A.B.C.D > no ip igmp static -group <A.B.C.D > Joins the interfa

Page 441

495EES4710BD 10 Slots L2/L3/L4 Chassis Switch z ip igmp version z show ip igmp groups z show ip igmp interface z debug ip igmp event z debu

Page 442

496EES4710BD 10 Slots L2/L3/L4 Chassis Switch 19.6.2.2.3 ip igmp query-interval Command: ip igmp query-interval <time_val> no ip igmp q

Page 443

497EES4710BD 10 Slots L2/L3/L4 Chassis Switch as the querier for that shared network, the other switches act as timers monitoring the status of

Page 444

498EES4710BD 10 Slots L2/L3/L4 Chassis Switch appropriate vlan, and PIM-DM protocol is enabled on each vlan interface. SWITCHASWITCHBEt her n

Page 445

4EES4710BD 10 Slots L2/L3/L4 Chassis Switch 2.3.1.2 Rack-mounting ES4710BD...

Page 446 - 18.5 WEB MANAGEMENT

49EES4710BD 10 Slots L2/L3/L4 Chassis Switch 1.4.3.1 EM4710BD-AC (Alternating Current Power Module) When powered by AC inputs, the AC power

Page 447 - 18.5.2.1.1 Enable RIP

499EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch#show ip igmp groups IGMP Connect Group Membership (1 group(s) joined) Group Address In

Page 448

500EES4710BD 10 Slots L2/L3/L4 Chassis Switch command disables this debug function. Parameters: N/A. Default: Disabled Command mode: Adm

Page 449

501EES4710BD 10 Slots L2/L3/L4 Chassis Switch 19.7 WEB MANAGEMENT Click “root page” left content column “Multicast protocol configuration” to

Page 450 - 18.5.3 OSPF

502EES4710BD 10 Slots L2/L3/L4 Chassis Switch z Query-Interval - Configures local interface PIM-DM hello message interval time z Vlan Port

Page 451

503EES4710BD 10 Slots L2/L3/L4 Chassis Switch 19.7.3.4 Set router as BSR candidate Click Set router as BSR candidate for configure PIM-SM

Page 452

504EES4710BD 10 Slots L2/L3/L4 Chassis Switch z Vlan Port - assigns layer 3 interface(select from scroll bar menu) z Apply - runs accordin

Page 453

505EES4710BD 10 Slots L2/L3/L4 Chassis Switch same as CLI command 19.5.2.2.3 z Interval of sending probe packet - Configures the interval of se

Page 454

506EES4710BD 10 Slots L2/L3/L4 Chassis Switch z IGMP query timeout - Configures IGMP query timeout. This is the same as CLI command 19.6.2.2.5

Page 455

507EES4710BD 10 Slots L2/L3/L4 Chassis Switch Click “Show ip pim neighbor” to display PIM interface neighbor information. This is the same as CL

Page 456 - 18.5.3.5 OSPF debug

508EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter20 802.1x Configuration 20.1 Introduction to 802.1x IEEE 802.1x is a port-based network a

Page 457 - 18.5.4 Display routing table

50EES4710BD 10 Slots L2/L3/L4 Chassis Switch VAC input socket for the positioning of power cords and easier wiring. In addition, on the left sid

Page 458 - 19.1.2 Multicast Address

509EES4710BD 10 Slots L2/L3/L4 Chassis Switch In the IEEE 802.1x application environment, ES4710BD is used as the access management unit, and th

Page 459

510EES4710BD 10 Slots L2/L3/L4 Chassis Switch 2. Access management unit property configuration 1) Configure port authentication status 2) Confi

Page 460 - 19.2.1.1 show ip mroute

511EES4710BD 10 Slots L2/L3/L4 Chassis Switch 3) Configure expanded 802.1x function: for the switch. 3. Supplicant related property configura

Page 461

512EES4710BD 10 Slots L2/L3/L4 Chassis Switch Global Mode radius-server key <string> no radius-server key Specifies the key for RADIUS

Page 462 - 19.3 PIM-DM

513EES4710BD 10 Slots L2/L3/L4 Chassis Switch Usage Guide: The AAA authentication for the switch must be enabled first to enable IEEE 802.1x aut

Page 463 - 19.3.2.3 ip pim dense-mode

514EES4710BD 10 Slots L2/L3/L4 Chassis Switch 20.2.2.4 dot1x eapor enable Command: dot1x eapor enable no dot1x eapor enable Function: Enables t

Page 464

515EES4710BD 10 Slots L2/L3/L4 Chassis Switch authentication packets support must be enabled in the switch, otherwise many application would not

Page 465

516EES4710BD 10 Slots L2/L3/L4 Chassis Switch Default: The default maximum user allowed is 1. Usage Guide: This command is available for ports u

Page 466

517EES4710BD 10 Slots L2/L3/L4 Chassis Switch specified port. Parameters: <interface-nam> stands for port number, omitting the parameter

Page 467

518EES4710BD 10 Slots L2/L3/L4 Chassis Switch Parameters: <seconds> is the interval for re-authentication, in seconds, the valid range is

Page 468 - 19.3.4.5 debug ip pim

51EES4710BD 10 Slots L2/L3/L4 Chassis Switch 1.4.8 Rear Panel The rear panel of the ES4710BD covers the switch backplane. To ensure safe operat

Page 469 - 19.4 PIM-SM

519EES4710BD 10 Slots L2/L3/L4 Chassis Switch servers, and all the accounting servers can be backup servers for each other. If primary is specif

Page 470 - 19.4.2 PIM-SM Configuration

520EES4710BD 10 Slots L2/L3/L4 Chassis Switch 20.2.2.20 radius-server key Command: radius-server key <string> no radius-server key Functio

Page 471

521EES4710BD 10 Slots L2/L3/L4 Chassis Switch time, the switch resends the request packet or sets the server as invalid according to the current

Page 472

522EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch(Config-Ethernet1/2)#exit 20.4 802.1x Troubleshooting 2o.4.1 802.1x Debug and Monitor Com

Page 473

523EES4710BD 10 Slots L2/L3/L4 Chassis Switch .Udp Port = 1813 .Is Primary = 0

Page 474

524EES4710BD 10 Slots L2/L3/L4 Chassis Switch Usage Guide: Usually the administrator is concerned only with the online user information, the oth

Page 475

525EES4710BD 10 Slots L2/L3/L4 Chassis Switch The total user num is: 1 2. Display the statistics for RADIUS authenticated users and

Page 476

526EES4710BD 10 Slots L2/L3/L4 Chassis Switch Supplicant 00-03-0F-FE-2E-D3 Authenticator State Machine State Aut

Page 477

527EES4710BD 10 Slots L2/L3/L4 Chassis Switch process and is helpful in troubleshooting. Example: Enabling AAA debugging information. Switch

Page 478 - 19.4.4.1.6 debug ip pim

528EES4710BD 10 Slots L2/L3/L4 Chassis Switch 20.5 WEB MANAGEMENT Click “Authentication configuration”, to open authentication configuration ma

Page 479

52EES4710BD 10 Slots L2/L3/L4 Chassis Switch 1.5 System Features Table 1.11 ES4710BD System Features SDRAM 128MB FLASH 32MB Status indicator:

Page 480 - 19.5 DVMRP

529EES4710BD 10 Slots L2/L3/L4 Chassis Switch 20.5.1.2 RADIUS authentication configuration Click “Authentication configuration”, “RADIUS clie

Page 481 - 19.5.2 DVMRP configuration

530EES4710BD 10 Slots L2/L3/L4 Chassis Switch 20.5.1.3 RADIUS accounting configuration Click “Authentication configuration”, “RADIUS client con

Page 482

531EES4710BD 10 Slots L2/L3/L4 Chassis Switch suppliant. Equivalent to CLI command 20.2.2.12. z Holddown time for authentication failure(1-65

Page 483

532EES4710BD 10 Slots L2/L3/L4 Chassis Switch z Authentication mode – Configures the access control method for a specific port. Mac-based is ac

Page 484

533EES4710BD 10 Slots L2/L3/L4 Chassis Switch port 802.1x configuration information, and make re-authentication for the specific port. Same as C

Page 485

534EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter21 VRRP Configuration 21.1 Introduction to VRRP VRRP (Virtual Router Redundancy Protocol)

Page 486

535EES4710BD 10 Slots L2/L3/L4 Chassis Switch 2) Configure VRRP priority 3) Configure VRRP Timer intervals 4) Configure VRRP interface monitor

Page 487

536EES4710BD 10 Slots L2/L3/L4 Chassis Switch (1) Configure the preemptive mode for VRRP Command Explanation VRRP protocol configuration mode

Page 488

537EES4710BD 10 Slots L2/L3/L4 Chassis Switch Commands: virtual-ip <A.B.C.D> {master| backup} no virtual-ip Function: Configures the VRRP

Page 489

538EES4710BD 10 Slots L2/L3/L4 Chassis Switch must be configured first before starting Virtual Router. Example: Activating the Virtual Router

Page 490

53EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 2 Hardware Installation 2.1 Safety Information During the installation and use

Page 491

539EES4710BD 10 Slots L2/L3/L4 Chassis Switch Parameters: <string> stands for the VRRP authentication string. Default: There is no authent

Page 492 - 19.6 IGMP

540EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch(Config-Router-Vrrp)# priority 150 21.1.2.10 advertisement-interval Commands: advertisemen

Page 493 - 19.6.2 IGMP configuration

541EES4710BD 10 Slots L2/L3/L4 Chassis Switch Backup cannot changes its status due to lower priority than the Master when the Master fails. Ex

Page 494

542EES4710BD 10 Slots L2/L3/L4 Chassis Switch 21.3.1 Monitor and Debug Commands 21.3.1.1 show vrrp Commands: show vrrp [<vrid>] Functi

Page 495

543EES4710BD 10 Slots L2/L3/L4 Chassis Switch Default: Debugging information is disabled by default. Command mode: Admin Mode Example: Switch

Page 496

544EES4710BD 10 Slots L2/L3/L4 Chassis Switch 21.4.2 Configure VRRP Dummy IP Click “VRRP control” to configure VRRP and enter "VRRP Dummy

Page 497

545EES4710BD 10 Slots L2/L3/L4 Chassis Switch to configure the preemptive mode for virtual router number 1 to "True". 21.4.6 Confi

Page 498

546EES4710BD 10 Slots L2/L3/L4 Chassis Switch Example: Choose created "Vlan1" for Port and "yes" for AuthenMode. Click Apply

Page 499

54EES4710BD 10 Slots L2/L3/L4 Chassis Switch (including rings, necklaces, watches and bracelets). 2. Metal objects will cause short circuits

Page 500

55EES4710BD 10 Slots L2/L3/L4 Chassis Switch ! Watch out for potential dangers, e.g. wet floors, ungrounded power lines, and worn power li

Page 501

56EES4710BD 10 Slots L2/L3/L4 Chassis Switch Temperature: Relative humidity Long term condition Short term condition Long term condition Shor

Page 502 - 19.7 WEB MANAGEMENT

57EES4710BD 10 Slots L2/L3/L4 Chassis Switch 2.1.4 Preventing Electrostatic Discharge Damage Static electric discharges can cause damage to int

Page 503

58EES4710BD 10 Slots L2/L3/L4 Chassis Switch 2.1.7 Power Supply Requirements The ES4710BD is designed to use modular switching power supplies,

Page 504 - 19.7.4.1 Enable DVMRP

5EES4710BD 10 Slots L2/L3/L4 Chassis Switch 4.2.1.1.3.2 VLAN Mode ...

Page 505

59EES4710BD 10 Slots L2/L3/L4 Chassis Switch A basic configuration ES4710BD should include the following: ITEM No. Part name Number Memo

Page 506 - 19.7.5 IGMP configuration

60EES4710BD 10 Slots L2/L3/L4 Chassis Switch & Cards and modules installation & Connecting to the Console  Connecting to the Con

Page 507

61EES4710BD 10 Slots L2/L3/L4 Chassis Switch & Copper Cable/Fiber cable connection  Ethernet cable connection  Fiber cable connection &

Page 508

62EES4710BD 10 Slots L2/L3/L4 Chassis Switch The figure below shows the steps for mounting the hangers: Fig 2-1 Installing ES4710BD

Page 509 - 20.1 Introduction to 802.1x

63EES4710BD 10 Slots L2/L3/L4 Chassis Switch z Proper grounding When using an AC power source, the device must be grounded with the green and

Page 510 - 20.2 802.1x Configuration

64EES4710BD 10 Slots L2/L3/L4 Chassis Switch 2.3.3.1 Removing and Installing the Cards The installation procedure is the same for all cards

Page 511

65EES4710BD 10 Slots L2/L3/L4 Chassis Switch front panel of the fan tray will lock automatically. Upon removal, hold the handle in the front pan

Page 512

66EES4710BD 10 Slots L2/L3/L4 Chassis Switch z Cleaning of power supply dust gauze: Dust gauzes are provided in the front panels of

Page 513 - 20.2.2.1 aaa enable

67EES4710BD 10 Slots L2/L3/L4 Chassis Switch 2.3.5 Connecting to the Management Port The EM4710BD-AGENT provides a RJ-45 (female) Ethernet port.

Page 514 - 20.2.2.3 dot1x accept-mac

68EES4710BD 10 Slots L2/L3/L4 Chassis Switch Step 4: Tighten (clockwise) the panel fasteners in the front of XENPAK transceiver until fastene

Page 515 - 20.2.2.5 dot1x enable

6EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.2.2.3.2 telnet ...

Page 516 - 20.2.2.9 dot1x max-user

69EES4710BD 10 Slots L2/L3/L4 Chassis Switch Step 1: Before connecting the AC power cable, ensure that the ES4710BD is properly grounded and

Page 517 - 20.2.2.11 dot1x port-method

70EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 3 Setup Configuration Setup configuration refers to the initial operation of the switch a

Page 518

71EES4710BD 10 Slots L2/L3/L4 Chassis Switch Selection number: The corresponding menu items in Chinese are: 配置菜 [0]:配置交机主机名 [1]:配置 Vlan1 的接口 [

Page 519

72EES4710BD 10 Slots L2/L3/L4 Chassis Switch The corresponding prompt in Chinese is: 配置 Vlan1 接口 [0]: 配置 Vlan1 接口的 IP 地址 [1]: 配置 Vlan1 接口的状

Page 520

73EES4710BD 10 Slots L2/L3/L4 Chassis Switch [0]: Add telnet user [1]: Config telnet server status [2]: Exit Selection number: The cor

Page 521 - 20.2.2.20 radius-server key

74EES4710BD 10 Slots L2/L3/L4 Chassis Switch enable Telnet service. The Telnet server configuration menu will then appear. Select “2” in the

Page 522 - 10. 1. 1. 3

75EES4710BD 10 Slots L2/L3/L4 Chassis Switch Note: valid password length is 1 to 8 characters. After configuring the username and password, the

Page 523 - 20.4.1.1 show aaa config

76EES4710BD 10 Slots L2/L3/L4 Chassis Switch [2]: 配置 Traps 主机 IP 地址和体字符串 [3]: 配置交机 SNMP 状 [4]: 配置交机 Traps 状 [5]: 添加 SNMP 管理站安全 IP 地址

Page 524

77EES4710BD 10 Slots L2/L3/L4 Chassis Switch Select “3” in the SNMP configuration menu and press Enter, the following screen will appear: Enab

Page 525 - 20.4.1.4 show radius count

78EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 4 Switch Management 4.1 Management Options After purchasing the switch, the user needs to

Page 526 - 20.4.1.5 show dot1x

7EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.4.4.2.6 snmp-server securityip...

Page 527 - 20.4.1.6 debug aaa

79EES4710BD 10 Slots L2/L3/L4 Chassis Switch Step 2 Entering the HyperTerminal. Open HyperTerminal in Windows after the connection has been

Page 528 - 20.4.1.7 debug dot1x

80EES4710BD 10 Slots L2/L3/L4 Chassis Switch Fig 4-4 Opening HyperTerminal (3) 4) COM1 properties appears, select “9600” for “Baud rate”, “8” f

Page 529 - 20.5 WEB MANAGEMENT

81EES4710BD 10 Slots L2/L3/L4 Chassis Switch Fig 4-6 Opening HyperTerminal (5) Step 3 Entering switch CLI interface: Power on the switch.

Page 530

82EES4710BD 10 Slots L2/L3/L4 Chassis Switch Current time is WED APR 20 09:37:52 2005

Page 531 - 20.5.2 802.1X configuration

83EES4710BD 10 Slots L2/L3/L4 Chassis Switch Fig 4-7 Managing the switch by Telnet Step 1: Configure the IP addresses for the switch and sta

Page 532

84EES4710BD 10 Slots L2/L3/L4 Chassis Switch Run the Telnet client program included in Windows with the specified Telnet target. Fig 4-8 Ru

Page 533

85EES4710BD 10 Slots L2/L3/L4 Chassis Switch Fig 4-9 Telnet Configuration Interface 4.1.2.2 Managing the Switch through ECview To manage

Page 534

86EES4710BD 10 Slots L2/L3/L4 Chassis Switch 4.2.1 CLI Interface CLI interface is familiar to most users. As aforementioned, out-of-band manage

Page 535 - 21.1 Introduction to VRRP

87EES4710BD 10 Slots L2/L3/L4 Chassis Switch 4.2.1.1.2 Admin Mode Admin Mode prompt “Switch#” can be entered under the User Mode by running the

Page 536

88EES4710BD 10 Slots L2/L3/L4 Chassis Switch under Global Mode. mode, speed, etc. 4.2.1.1.3.2 VLAN Mode Using the vlan <vlan-id> comma

Page 537 - 21.1.2.2 virtual-ip

8EES4710BD 10 Slots L2/L3/L4 Chassis Switch 5.6.2.3 Configure IP address of SNMP manager...

Page 538 - 21.1.2.4 enable

89EES4710BD 10 Slots L2/L3/L4 Chassis Switch extended command under Global Mode. for Extended IP ACL Mode return to Global Mode. 4.2.1.2 Confi

Page 539 - 21.1.2.5 disable

90EES4710BD 10 Slots L2/L3/L4 Chassis Switch Right “→” The cursor moves one character to the right. Ctrl+p The same as Up key “↑”. Ctrl+n

Page 540 - 21.1.2.9 priority

91EES4710BD 10 Slots L2/L3/L4 Chassis Switch Unrecognized command or illegal parameter! The entered command does not exist, or there is error in

Page 541 - 21.1.2.11 circuit-failover

92EES4710BD 10 Slots L2/L3/L4 Chassis Switch 4.3.2 Module Front Panel When entering username, password and passing authentication, you wil

Page 542 - 21.2 Typical VRRP Scenario

93EES4710BD 10 Slots L2/L3/L4 Chassis Switch Chapter 5 Basic Switch Configuration 5.1 Basic Switch Configuration Commands This section covers

Page 543 - 21.3.1.2 debug vrrp

94EES4710BD 10 Slots L2/L3/L4 Chassis Switch user password are all wrong, it remains in the User Mode. Set the Admin user password under Global

Page 544 - 21.4 WEB MANAGEMENT

95EES4710BD 10 Slots L2/L3/L4 Chassis Switch Default: The default value is 5 minutes. Usage Guide: To ensure security for the switch and preve

Page 545 - 21.4.3 Configure VRRP Port

96EES4710BD 10 Slots L2/L3/L4 Chassis Switch Parameters: <hostname> is the host name, up to 15 characters are allowed; <ip_addr> is

Page 546

97EES4710BD 10 Slots L2/L3/L4 Chassis Switch Switch#reload 5.1.12 setup Command: setup Function: Enters the Setup Mode of the switch. Comman

Page 547

98EES4710BD 10 Slots L2/L3/L4 Chassis Switch Function: The switch sends an ICMP packet to remote devices to verify the connectivity between the

Comments to this Manuals

No comments